Troubleshooting
A field inside my Block lost its scene object
Blocks are assets and can't keep references to scene objects. Pass the object in through Source, Target or a Game Object parameter. Move Instructions to Block does this for you.
"Parameters > Block Parameter" is missing
It only appears while editing a Block, and only lists parameters the field can read. Check that the Block has a parameter of a matching type. If you just added a new value type, wait for the script reload, or use Tools > LogicBlock 2 > Regenerate Parameters.
My own value type doesn't appear in Add Parameter
It must be a public, non-abstract TSignalGet (a Get value) with a public parameterless constructor. If it lives in an assembly definition, that assembly must have Auto Referenced on and must not be editor-only.
A call's parameter field isn't blue, but I changed it
If the value equals the Block's default, it isn't marked as changed. That's intentional: it follows the Block again.
Console: "calls are nested more than 32 levels deep"
A Block is (directly or indirectly) running itself. Add a condition that stops the recursion, or use Is Block Running.
Parameters disappeared from my Blocks after moving the project or the plugin folder
Saved parameter values remember which assembly their generated type lives in. Keep Assets/Plugins/LogicBlock2/Generated Parameters where it is.
Compile errors in a generated file
They usually fix themselves on the next compile, because broken generated files are removed. Otherwise use Tools > LogicBlock 2 > Regenerate Parameters. Don't edit generated files.